CVSS 7.099999904632568 HIGH
The web interface of SIMATIC S7-1200 CPUs before V4.7 is affected by a cross-site request forgery (CSRF) vulnerability. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Risk Scores
CVSS v3.1
7.099999904632568
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:H/E:P/RL:O/RC:C
Affected Products
| Vendor | Product | Versions |
|---|---|---|
| SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0) | ||
| SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0) | ||
| SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0) | ||
| SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0) | ||
| SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0) | ||
| SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0) | ||
| SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0) | ||
| SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0) | ||
| SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0) | ||
| SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0) | ||
| SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0) | ||
| SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0) | ||
| SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0) | ||
| SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0) | ||
| SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0) | ||
| SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0) | ||
| SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0) | ||
| SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0) | ||
| SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0) | ||
| SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0) |
Timeline
- Jan 14, 2025 CVE Published
- May 6, 2025 CVE Updated
References
- https://cert-portal.siemens.com/productcert/csaf/ssa-717113.json advisory
- https://cert-portal.siemens.com/productcert/html/ssa-717113.html advisory
- https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-021-02.json advisory
- https://www.cisa.gov/news-events/ics-advisories/icsa-25-021-02 advisory
- https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01 url
- https://www.cisa.gov/resources-tools/resources/ics-recommended-practices url
- https://www.cisa.gov/topics/industrial-control-systems url
- https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf url
- https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf url
- https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B url
- https://support.industry.siemens.com/cs/ww/en/view/109976907/ fix