VDB
ICSA-24-228-09
ICSA-24-228-09
PUBLISHED
CVSS 7.800000190734863 HIGH
NX (incl. NX student versions) before V2406.3000 contains an out-of-bounds read vulnerability that could be triggered when the application reads PRT files. If a user is tricked to open a malicious file using the affected application, this could lead to a crash, and potentially also to arbitrary code execution on the target host system. Siemens has released a new version for NX and recommends to update to the latest version.
Risk Scores
CVSS v3.1
7.800000190734863
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Affected Products
| Vendor | Product | Versions |
|---|---|---|
| NX |
Timeline
- Aug 13, 2024 CVE Published
References
- https://cert-portal.siemens.com/productcert/csaf/ssa-357412.json advisory
- https://cert-portal.siemens.com/productcert/html/ssa-357412.html advisory
- https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-228-09.json advisory
- https://www.cisa.gov/news-events/ics-advisories/icsa-24-228-09 advisory
- https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01 url
- https://www.cisa.gov/resources-tools/resources/ics-recommended-practices url
- https://www.cisa.gov/topics/industrial-control-systems url
- https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf url
- https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf url
- https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B url