VDB

CVE-2026-67279

CVE-2026-67279 PUBLISHED CVSS 6.9 MEDIUM

Reported by CERT-PL · Published September 5, 2026

RouterOS SSH enters the connection protocol after a client-requested rekey even though user authentication was never attempted, allowing an unauthenticated client to open a session channel and send an exec request. On affected builds the server dispatches the command, enabling unauthenticated creation, overwrite, and reconstruction of files in the RouterOS managed file namespace, including support files containing configuration and diagnostic data.This issue was fixed in versions: 6.49.21 (Long-term), 7.23.4 (Long-term) and 7.24.2 (Stable)

Risk Scores

CVSS 4.0
6.9
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N

Affected Products

VendorProductVersions
MikrotikRouterOS7.24, 7.0.0, 6.0.0
MikrotikRouterOS6.0.0, 7.24, 7.0.0
mikrotikrouteros0.0.0, 0.0.0

Timeline

  • Sep 5, 2026 Coalition ESS Score
  • Sep 5, 2026 CVE Published
  • Sep 6, 2026 EPSS Score
  • Sep 8, 2026 CVE Updated
  • Sep 9, 2026 EPSS Score
  • Sep 12, 2026 EPSS Score
  • Sep 16, 2026 EPSS Score
  • Sep 18, 2026 EPSS Score

References

  • third-party-advisory
  • technical-description
  • exploit
  • vendor-advisory
  • release-notes
  • release-notes
  • release-notes
Open in Interactive Console →
$ Console Community · 100/wk Open console ›