CVE-2023-30755
Reported by siemens · Published September 10, 2024
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.5.20), SIMATIC CP 1243-7 LTE (All versions < V3.5.20), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.5.20), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMATIC WinCC Runtime Advanced (All versions), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.4.8), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.4.8). The web server of the affected devices do not properly handle the shutdown or reboot request, which could lead to the clean up of certain resources. This could allow a remote attacker with elevated privileges to cause a denial of service condition in the system.
Fixed versions
Upgrade to a fixed version or later. Language registries are listed first, then Linux distributions, then vendor products.
| Package | Ecosystem | Fixed in |
|---|---|---|
| SIMATIC CP 1243-1 (incl. SIPLUS variants) | Siemens | 3.5.20 |
Risk scores
Affected products
| Vendor | Product | Versions |
|---|---|---|
| Siemens | SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) | 0 |
| Siemens | SIMATIC CP 1243-1 (incl. SIPLUS variants) | 0 |
| Siemens | SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) | 0 |
| Siemens | SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) | 0 |
| Siemens | SIMATIC CP 1243-7 LTE | 0 |
| Siemens | SIMATIC CP 1243-8 IRC | 0 |
| Siemens | SIMATIC HMI Comfort Panels (incl. SIPLUS variants) | All versions |
| Siemens | SIMATIC IPC DiagBase | 0 |
| Siemens | SIMATIC IPC DiagMonitor | All versions |
| Siemens | SIMATIC WinCC Runtime Advanced | All versions |
| Siemens | SIPLUS TIM 1531 IRC | 0 |
| Siemens | TIM 1531 IRC | 0 |
| Siemens | SIMATIC CP 1243-1 (incl. SIPLUS variants) | 0 |
| Siemens | SIMATIC HMI Comfort Panels (incl. SIPLUS variants) | * |
| Siemens | SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) | 0 |
| Siemens | SIMATIC CP 1243-8 IRC | 0 |
| Siemens | SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) | 0 |
| Siemens | SIMATIC CP 1243-7 LTE | 0 |
| Siemens | TIM 1531 IRC | 0 |
| Siemens | SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) | 0 |
…and 4 more
Timeline
- Sep 9, 2024 CVE Published
- Sep 11, 2024 EPSS Score (30 in total, the first dated here)
- Feb 16, 2026 CVE Updated
- May 2, 2026 Security Advisory
Query this with the API
The same record, from the CLI:
vulnetix vdb vuln CVE-2023-30755
vulnetix vdb fixes CVE-2023-30755
Or with curl, using the org id and key from your account page:
curl -s -H "Authorization: ApiKey ${VULNETIX_ORG_ID}:${VULNETIX_API_KEY}" \
"https://api.vdb.vulnetix.com/v2/vuln/CVE-2023-30755/fixes/registry"