VDB

CISA-2025-47809

CISA-2025-47809 PUBLISHED CVSS 8.2 HIGH

Reported by mitre · Published May 16, 2025

Wibu CodeMeter before 8.30a sometimes allows privilege escalation immediately after installation (before a logoff or reboot). For exploitation, there must have been an unprivileged installation with UAC, and the CodeMeter Control Center component must be installed, and the CodeMeter Control Center component must not have been restarted. In this scenario, the local user can navigate from Import License to a privileged instance of Windows Explorer.

Risk Scores

CVSS 3.1
8.2
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Affected Products

VendorProductVersions
WibuCodeMeter0
WibuCodeMeter0, 0
wibucodemeter0, 0

Timeline

  • May 16, 2025 CVE Published
  • May 16, 2025 CVE Updated

References

Open in Interactive Console →
$ Console Community · 100/wk Open console ›